Blood flow characteristics of diabetic patients with complications detected by optical measurement

Cited 13 time in webofscience Cited 0 time in scopus
  • Hit : 610
  • Download : 153
DC FieldValueLanguage
dc.contributor.authorAn, Yuriko
dc.contributor.authorKang, Yujungko
dc.contributor.authorLee, Jungsulko
dc.contributor.authorAhn, Chulwooko
dc.contributor.authorKwon, Kihwanko
dc.contributor.authorChoi, Chulheeko
dc.date.accessioned2018-03-23T00:15:19Z-
dc.date.available2018-03-23T00:15:19Z-
dc.date.created2018-03-20-
dc.date.created2018-03-20-
dc.date.created2018-03-20-
dc.date.issued2018-02-
dc.identifier.citationBIOMEDICAL ENGINEERING ONLINE, v.17-
dc.identifier.issn1475-925X-
dc.identifier.urihttp://hdl.handle.net/10203/240939-
dc.description.abstractBackground: Diabetes mellitus (DM) is one of the most common diseases worldwide. Uncontrolled and prolonged hyperglycemia can cause diabetic complications, which reduce the quality of life of patients. Diabetic complications are common in DM patients. Because it is impossible to completely recover from diabetic complications, it is important for early detection. In this study, we suggest a novel method of determining blood flow characteristics based on fluorescence image analysis with indocyanine green and report that diabetic complications have unique blood flow characteristics. Methods: We analyzed time-series fluorescence images obtained from controls, DM patients, and DM patients with complications. The images were segmented into the digits and the dorsum of the feet and hands, and each part has been considered as arterial and capillary flow. We compared the blood flow parameters in each region among the three groups. Results: The DM patients with complications showed similar blood flow parameters to the controls, except the area under the curve and the maximum intensity, which indicate the blood flow volume. These parameters were significantly decreased in DM patients with complications. Although some blood flow parameters in the feet of DM patients with complications were close to normal blood flow, the vascular response of the macrovessels and microvessels to stimulation of the hands was significantly reduced, which indicates less reactivity in DM patients with complications. Conclusions: Our results suggest that DM patients, and DM patients with complications, have unique peripheral blood flow characteristics.-
dc.languageEnglish-
dc.publisherBIOMED CENTRAL LTD-
dc.subjectINDOCYANINE GREEN ANGIOGRAPHY-
dc.subjectPERIPHERAL VASCULAR-DISEASE-
dc.subjectNEAR-INFRARED SPECTROSCOPY-
dc.subjectPULSE-WAVE VELOCITY-
dc.subjectENDOTHELIAL FUNCTION-
dc.subjectMICROVASCULAR DYSFUNCTION-
dc.subjectQUANTITATIVE-EVALUATION-
dc.subjectCLINICAL-PRACTICE-
dc.subjectARTERIAL-DISEASE-
dc.subjectLASER-DOPPLER-
dc.titleBlood flow characteristics of diabetic patients with complications detected by optical measurement-
dc.typeArticle-
dc.identifier.wosid000426369200001-
dc.identifier.scopusid2-s2.0-85042399384-
dc.type.rimsART-
dc.citation.volume17-
dc.citation.publicationnameBIOMEDICAL ENGINEERING ONLINE-
dc.identifier.doi10.1186/s12938-018-0457-9-
dc.contributor.localauthorChoi, Chulhee-
dc.contributor.nonIdAuthorKang, Yujung-
dc.contributor.nonIdAuthorLee, Jungsul-
dc.contributor.nonIdAuthorAhn, Chulwoo-
dc.contributor.nonIdAuthorKwon, Kihwan-
dc.description.isOpenAccessY-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorDiabetes mellitus-
dc.subject.keywordAuthorDiabetic complications-
dc.subject.keywordAuthorBlood flow characteristic-
dc.subject.keywordAuthorMedical imaging-
dc.subject.keywordAuthorIndocyanine green-
dc.subject.keywordAuthorDiabetes mellitus-
dc.subject.keywordAuthorDiabetic complications-
dc.subject.keywordAuthorBlood flow characteristic-
dc.subject.keywordAuthorMedical imaging-
dc.subject.keywordAuthorIndocyanine green-
dc.subject.keywordPlusINDOCYANINE GREEN ANGIOGRAPHY-
dc.subject.keywordPlusPERIPHERAL VASCULAR-DISEASE-
dc.subject.keywordPlusNEAR-INFRARED SPECTROSCOPY-
dc.subject.keywordPlusPULSE-WAVE VELOCITY-
dc.subject.keywordPlusENDOTHELIAL FUNCTION-
dc.subject.keywordPlusMICROVASCULAR DYSFUNCTION-
dc.subject.keywordPlusQUANTITATIVE-EVALUATION-
dc.subject.keywordPlusCLINICAL-PRACTICE-
dc.subject.keywordPlusARTERIAL-DISEASE-
dc.subject.keywordPlusLASER-DOPPLER-
dc.subject.keywordPlusINDOCYANINE GREEN ANGIOGRAPHY-
dc.subject.keywordPlusPERIPHERAL VASCULAR-DISEASE-
dc.subject.keywordPlusNEAR-INFRARED SPECTROSCOPY-
dc.subject.keywordPlusPULSE-WAVE VELOCITY-
dc.subject.keywordPlusENDOTHELIAL FUNCTION-
dc.subject.keywordPlusMICROVASCULAR DYSFUNCTION-
dc.subject.keywordPlusQUANTITATIVE-EVALUATION-
dc.subject.keywordPlusCLINICAL-PRACTICE-
dc.subject.keywordPlusARTERIAL-DISEASE-
dc.subject.keywordPlusLASER-DOPPLER-
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 13 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley