Ultrasound-mediated drug delivery by gas bubbles generated from a chemical reaction

Cited 10 time in webofscience Cited 0 time in scopus
  • Hit : 579
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorLee, Sungmunko
dc.contributor.authorAl-Kaabi, Leenako
dc.contributor.authorMawart, Aurelieko
dc.contributor.authorKhandoker, Ahsanko
dc.contributor.authorAlsafar, Habibako
dc.contributor.authorJelinek, Herbert F.ko
dc.contributor.authorKhalaf, Kindako
dc.contributor.authorPark, Ji-Hoko
dc.contributor.authorKim, Yeu-Chunko
dc.date.accessioned2018-02-21T06:04:32Z-
dc.date.available2018-02-21T06:04:32Z-
dc.date.created2018-02-05-
dc.date.created2018-02-05-
dc.date.issued2018-01-
dc.identifier.citationJOURNAL OF DRUG TARGETING, v.26, no.2, pp.172 - 181-
dc.identifier.issn1061-186X-
dc.identifier.urihttp://hdl.handle.net/10203/240233-
dc.description.abstractHighly echogenic and ultrasound-responsive microbubbles such as nitrogen and perfluorocarbons have been exploited as ultrasound-mediated drug carriers. Here, we propose an innovative method for drug delivery using microbubbles generated from a chemical reaction. In a novel drug delivery system, luminol encapsulated in folate-conjugated bovine serum albumin nanoparticles (Fol-BSAN) can generate nitrogen gas (N-2) by chemical reaction when it reacts with hydrogen peroxide (H2O2), one of reactive oxygen species (ROS). ROS plays an important role in the initiation and progression of cancer and elevated ROS have been observed in cancer cells both in vitro and in vivo. High-intensity focussed ultrasound (HIFU) is used to burst the N-2 microbubbles, causing site-specific delivery of anticancer drugs such as methotrexate. In this research, the drug delivery system was optimised by using water-soluble luminol and Mobil Composition of Matter-41 (MCM-41), a mesoporous material, so that the delivery system was sensitive to micromolar concentrations of H2O2. HIFU increased the drug release from Fol-BSAN by 52.9 +/- 2.9% in 10minutes. The cytotoxicity of methotrexate was enhanced when methotrexate is delivered to MDA-MB-231, a metastatic human breast cancer cell line, using Fol-BSAN with HIFU. We anticipate numerous applications of chemically generated microbubbles for ultrasound-mediated drug delivery.-
dc.languageEnglish-
dc.publisherTAYLOR & FRANCIS LTD-
dc.subjectMICROBUBBLE CONTRAST AGENTS-
dc.subjectOXIDATIVE STRESS-
dc.subjectCANCER-TREATMENT-
dc.subjectGENE DELIVERY-
dc.subjectIN-VIVO-
dc.subjectTHERAPY-
dc.subjectMETHOTREXATE-
dc.subjectMONODISPERSE-
dc.subjectCAVITATION-
dc.subjectMECHANISMS-
dc.titleUltrasound-mediated drug delivery by gas bubbles generated from a chemical reaction-
dc.typeArticle-
dc.identifier.wosid000423412800008-
dc.identifier.scopusid2-s2.0-85024492335-
dc.type.rimsART-
dc.citation.volume26-
dc.citation.issue2-
dc.citation.beginningpage172-
dc.citation.endingpage181-
dc.citation.publicationnameJOURNAL OF DRUG TARGETING-
dc.identifier.doi10.1080/1061186X.2017.1354001-
dc.contributor.localauthorPark, Ji-Ho-
dc.contributor.localauthorKim, Yeu-Chun-
dc.contributor.nonIdAuthorLee, Sungmun-
dc.contributor.nonIdAuthorAl-Kaabi, Leena-
dc.contributor.nonIdAuthorMawart, Aurelie-
dc.contributor.nonIdAuthorKhandoker, Ahsan-
dc.contributor.nonIdAuthorAlsafar, Habiba-
dc.contributor.nonIdAuthorJelinek, Herbert F.-
dc.contributor.nonIdAuthorKhalaf, Kinda-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorHigh-intensity focussed ultrasound-
dc.subject.keywordAuthormicrobubble generation-
dc.subject.keywordAuthorreactive oxygen species-
dc.subject.keywordAuthorcancer-
dc.subject.keywordAuthorluminol-
dc.subject.keywordPlusMICROBUBBLE CONTRAST AGENTS-
dc.subject.keywordPlusOXIDATIVE STRESS-
dc.subject.keywordPlusCANCER-TREATMENT-
dc.subject.keywordPlusGENE DELIVERY-
dc.subject.keywordPlusIN-VIVO-
dc.subject.keywordPlusTHERAPY-
dc.subject.keywordPlusMETHOTREXATE-
dc.subject.keywordPlusMONODISPERSE-
dc.subject.keywordPlusCAVITATION-
dc.subject.keywordPlusMECHANISMS-
Appears in Collection
BiS-Journal Papers(저널논문)CBE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 10 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0