Data processing technique for data measured in MO image measurement system

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 470
  • Download : 0
We report processing technique in the MO image measurement system. Calibration procedure is not only considered to perpendicular field but also in-plane field. Current density and field profiles are obtained by Biot-savart law and inversion method. We show example of (Gd,Y)1Ba2Cu3O7-δ-BaZrO3 film that have tilted nano rod pinning centers about 13° from the c-axis.
Publisher
Korea Institute of Applied Superconductivity and Cryogenics
Issue Date
2013-03
Language
Korean
Citation

Journal of the Korea Institute of Applied Superconductivity and Cryogenics, v.15, no.1, pp.25 - 28

ISSN
1229-3008
DOI
10.9714/psac.2013.15.1.025
URI
http://hdl.handle.net/10203/202775
Appears in Collection
PH-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.