Pressure drop and heat transfer correlations for triangular folded fin heat sinks

Cited 6 time in webofscience Cited 0 time in scopus
  • Hit : 917
  • Download : 835
Experiments have been performed to investigate the cooling performance of triangular folded fin heat sinks made of 6000 series aluminum in a duct flow. The dimension of the triangular folded fin heat sink is 70 mm in width and 92 min in length with an 8-mm-thick base plate. The fin height is varied from 19 to 36 mm and the fin pitch from 5.0 to 9.0 mm. The duct air velocity is in the range of 1.0 to 5.0 m/s and the corresponding Reynolds number based on the hydraulic diameter is varied from 212 to 1974. The experimental results show that the cooling performance of triangular folded fin heat sink is influenced by the fin pitch, the Reynolds number, and the fin height. It increases substantially as the fin pitch decreases and the Reynolds number and the fin height increase. By compiling the experimental data, the heat transfer and the friction factor correlations with +/- 6.5% and +/- 20% accuracy, respectively, are provided for effective design of triangular folded fin heat sinks.
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Issue Date
2007-03
Language
English
Article Type
Article
Keywords

FORCED-CONVECTION; PERFORMANCE

Citation

IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES, v.30, no.1, pp.3 - 8

ISSN
1521-3331
DOI
10.1109/TCAPT.2006.885943
URI
http://hdl.handle.net/10203/1628
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 6 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0