소형 Gifford-McMahon/Joule-Thomson 냉동기에서 열교환기의 최적 조합Optimum Size Combination of Heat Exchangers in a Small Gifford-Mchon/ Joule-Thomson Refrigerator

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 635
  • Download : 18
The optimum size combination of heat exchangers in a Joule-Thomson(J-T) circuit for small cryogenic systems has been sought analytically, when the circuit is combined with a two-stage Gifford-McMahon(GM) cooler. Full thermodynamic cycle analysis was carried out to predict the performance of the combined refrigeration system. Relevant convective heat transfer coefficients, the computerized properties of helium, and the refrigeration capacity curve of a typical GM cooler have been used in the analysis. The result showed that, by changing the configuration(heat exchanger area ratio) of the system, the performance of the commonly-used GM/J-T refrigerators could be optimized. For the maximum refrigeration performance, the optimum mass flow rate of the refrigerant and the relative size between the heat exchangers have been obtained, when the cooling load was 0.1W at 3.995K with the total heat exchanger area being given.
Publisher
대한기계학회
Issue Date
1992-11
Language
Korean
Citation

대한기계학회논문집 A, v.16, no.11, pp.2196 - 2202

ISSN
1226-4873
URI
http://hdl.handle.net/10203/15246
Appears in Collection
ME-Journal Papers(저널논문)