Design and fabrication of integrated passive valves and pumps for flexible polymer 3-dimensional microfluidic systems

Cited 135 time in webofscience Cited 144 time in scopus
  • Hit : 340
  • Download : 147
DC FieldValueLanguage
dc.contributor.authorJeon, NLko
dc.contributor.authorChiu, DTko
dc.contributor.authorWargo, CJko
dc.contributor.authorWu, HKko
dc.contributor.authorChoi, Insungko
dc.contributor.authorAnderson, JRko
dc.contributor.authorWhitesides, GMko
dc.date.accessioned2009-11-20T06:07:13Z-
dc.date.available2009-11-20T06:07:13Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued2002-05-
dc.identifier.citationBIOMEDICAL MICRODEVICES, v.4, no.2, pp.117 - 121-
dc.identifier.issn1387-2176-
dc.identifier.urihttp://hdl.handle.net/10203/13002-
dc.description.abstractThis paper describes the fabrication of flexible, polymeric 3-dimensional microfluidic systems with integrated check valves (flap and diaphragm valves) and a pump by stacking patterned poly(dimethylsiloxane) (PDMS) layers containing microchannels and vias. We describe this procedure for fabricating, manipulating, and bonding of PDMS membranes and bas-relief plates into multilayer microfluidic devices. The fabrication and demonstration of integrated check valves and a pump in a prototype polymer 3-dimensional microfluidic system is a step toward practical realization of all-polymer, flexible, low-cost, disposable microfluidic devices for biochemical applications.-
dc.languageEnglish-
dc.language.isoen_USen
dc.publisherKLUWER ACADEMIC PUBL-
dc.subjectCAPILLARY ELECTROPHORESIS CHIPS-
dc.subjectCHEMICAL-ANALYSIS SYSTEMS-
dc.subjectPOLY(DIMETHYLSILOXANE)-
dc.subjectTECHNOLOGY-
dc.subjectASSAYS-
dc.subjectPDMS-
dc.titleDesign and fabrication of integrated passive valves and pumps for flexible polymer 3-dimensional microfluidic systems-
dc.typeArticle-
dc.identifier.wosid000177696700006-
dc.identifier.scopusid2-s2.0-0036239107-
dc.type.rimsART-
dc.citation.volume4-
dc.citation.issue2-
dc.citation.beginningpage117-
dc.citation.endingpage121-
dc.citation.publicationnameBIOMEDICAL MICRODEVICES-
dc.identifier.doi10.1023/A:1014683114796-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.contributor.localauthorChoi, Insung-
dc.contributor.nonIdAuthorJeon, NL-
dc.contributor.nonIdAuthorChiu, DT-
dc.contributor.nonIdAuthorWargo, CJ-
dc.contributor.nonIdAuthorWu, HK-
dc.contributor.nonIdAuthorAnderson, JR-
dc.contributor.nonIdAuthorWhitesides, GM-
dc.type.journalArticleArticle-
dc.subject.keywordAuthormicrofluidies-
dc.subject.keywordAuthorvalves-
dc.subject.keywordAuthorPDMS-
dc.subject.keywordPlusCAPILLARY ELECTROPHORESIS CHIPS-
dc.subject.keywordPlusCHEMICAL-ANALYSIS SYSTEMS-
dc.subject.keywordPlusPOLY(DIMETHYLSILOXANE)-
dc.subject.keywordPlusTECHNOLOGY-
dc.subject.keywordPlusASSAYS-
dc.subject.keywordPlusPDMS-
Appears in Collection
CH-Journal Papers(저널논문)
Files in This Item
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 135 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0