햅틱 기반 정맥주사 시뮬레이터를 위한 생체조직 바늘 삽입력Needle Insertion Force of Biological Soft Tissue for Haptic based Intravenous Injection Simulator

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 769
  • Download : 0
DC FieldValueLanguage
dc.contributor.author안범모ko
dc.contributor.author정은영ko
dc.contributor.author이영호ko
dc.contributor.author임용수ko
dc.contributor.author박래웅ko
dc.contributor.author김정ko
dc.contributor.author박동균ko
dc.date.accessioned2013-03-12T04:50:54Z-
dc.date.available2013-03-12T04:50:54Z-
dc.date.created2012-05-31-
dc.date.created2012-05-31-
dc.date.issued2012-02-
dc.identifier.citation한국정밀공학회지, v.29, no.2, pp.222 - 228-
dc.identifier.issn1225-9071-
dc.identifier.urihttp://hdl.handle.net/10203/101365-
dc.description.abstractHaptics and virtual reality are rapidly growing technologies in medical fields. Physicians and nurses can benefit from medical simulation via training and acquire surgical and clinical techniques. In this paper, the research on needle insertion force of biological tissue for haptic based intravenous injection simulator was carried out. We built the setup for needle insertion (intravenous injection) experiments and performed the experiments on live pigs. The force responses against needle insertion were measured using the experimental setup. In addition, the modeling of needle insertion force was carried out with the experimental results and numerical models via nonlinear least-squares method. The results presented in this paper indicate that the developed models can be applied not only to estimate the force feedback during intravenous injection procedure but also to improve the overall training quality of the medical simulator.-
dc.languageKorean-
dc.publisher한국정밀공학회-
dc.title햅틱 기반 정맥주사 시뮬레이터를 위한 생체조직 바늘 삽입력-
dc.title.alternativeNeedle Insertion Force of Biological Soft Tissue for Haptic based Intravenous Injection Simulator-
dc.typeArticle-
dc.type.rimsART-
dc.citation.volume29-
dc.citation.issue2-
dc.citation.beginningpage222-
dc.citation.endingpage228-
dc.citation.publicationname한국정밀공학회지-
dc.identifier.kciidART001629549-
dc.contributor.localauthor김정-
dc.contributor.nonIdAuthor안범모-
dc.contributor.nonIdAuthor정은영-
dc.contributor.nonIdAuthor이영호-
dc.contributor.nonIdAuthor임용수-
dc.contributor.nonIdAuthor박래웅-
dc.contributor.nonIdAuthor박동균-
dc.description.isOpenAccessN-
dc.subject.keywordAuthor촉감/햅틱-
dc.subject.keywordAuthor정맥주사-
dc.subject.keywordAuthor의료시뮬레이터-
dc.subject.keywordAuthor바늘삽입력모델-
dc.subject.keywordAuthorHaptic-
dc.subject.keywordAuthorIntravenous Injection-
dc.subject.keywordAuthorMedical Simulator-
dc.subject.keywordAuthorNeedle Insertion Force Model-
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0